Since, the spacing between individual equipment items is reduced, expenditure on piping is reduced. Once more we stress the savings associated with size and weight reduction can only be achieved if these advantages are recognized at the earliest stages of the plant design.
The alternative technologies result in reduced complexity by reducing the number of heat exchangers. This is achieved through:
- improved ‘thermal contacting’
- multi-streaming.
Thermal expansion considerations can also lead the designer to opt for multiple tube passes for the cost of a floating head is generally lower than the cost of installing an expansion bellows in the exchanger shell.
The use of multiple tube passes has four detrimental effects. First, it leads to a reduction in the number of tubes that can be accommodated in a given size of shell (so it leads to increased shell diameter and cost). Second, for bundles having more than four tube passes, the pass partition lanes introduced into the bundle give rise to an increase in the quantity of shell-side fluid bypassing the tube bundle and a reduction in tube-side heat transfer coefficient. Thirdly, it gives rise to wasted tube side pressure drop in the return headers. Finally, and most significantly, the use of multiple tube passes results in the thermal contacting of the streams not being pure counter-flow. This has two effects. The first is that the Effective Mean Temperature Driving Force is reduced. The second, and more serious effect, is that a ‘temperature cross’ can occur.
If a ‘temperature cross’ occurs, the designer must split the duty between a number of individual heat exchangers arranged in series. Figures 1 and 2 below illustrate the difference between temperatures that are said to be ‘crossing’ and those that are not.
Many of the alternative heat exchanger technologies allow the application of pure counter-flow across all size and flow ranges. The results are better use of available temperature driving force and the use of single heat exchangers.
Let’s now consider multi-streaming. The traditional shell-and-tube heat exchanger only handles one hot and one cold stream. Some heat exchanger technologies (most notably plate-fin and printed circuit exchangers) can handle many streams. It is not uncommon to find plate-fin heat exchangers transferring heat between ten individual process. Such units can be considered to contain a whole heat exchanger network within the body of a single exchanger. Distribution and recombination of process flows is undertaken inside the exchanger. The result is a major saving in piping cost.
Engineers often over-look the opportunities of using a plate and frame unit as a multi-stream unit. (Again, this will be a regular oversight if exchanger selection is not made until after the flow sheet has been developed).
A good example of multi-streaming is the use of a plate heat exchanger serving as a process interchanger on one side and a trim cooler on the other. This arrangement is particularly useful for product streams that are exiting a process and must be cooled for storage. Another popular function of multi-streaming is in lowering material costs. Often times, once streams are cooled to a certain temperature, they pose much less of a corrosion risk. Half of the exchanger can contain a higher alloy, while the other side can utilize stainless steel or a lower alloy.
In Figure 3 we show how a plate and frame unit has been applied to a problem involving three process streams. The heat transfer properties used for styrene are given in Table 1. Just one unit is used and this unit has 1,335 sq.ft. of effective surface area.
In Figure 4 we show the equivalent shell-and-tube solution. In order to avoid temperature crosses we need six individual exchangers: the cooler having two shells in series (each having 1,440 sq.ft of effective surface); the heat recovery unit having four shells in series (each having 2,116 sq.ft. of surface).
So, our plate-and-frame design involves the use of 1,335 sq.ft. of surface in a single unit. The equivalent shell-and-tube design has 11,344 sq.ft. of surface distributed across four separate exchangers.
100 °F | 150 °F | 200 °F | |
Density (lb/ft3) | 55.5 | 53.9 | 52.3 |
Specific Heat (Btu/lb 0F) | 0.427 | 0.447 | 0.471 |
Viscosity (cP) | 0.590 | 0.428 | 0.329 |
Thermal Cond. (Btu/ft h 0F) | 0.077 | 0.074 | 0.070 |